Uninterruptible Power Supplies (UPS)
Online double-conversion UPS from 1 to 800 kVA, standalone and modular.

A UPS feeds the load without a moment of interruption and bridges the time until the generator starts. We offer online double-conversion systems (VFI to IEC 62040-3), where the output voltage is fully independent of mains variations and disturbances.
We size power and autonomy to the load. Modular systems grow with demand: a power module is added without stopping operation.
Key benefits
- Clean, stable voltage for sensitive equipment
- N+1 redundancy with parallel operation
- Expansion without downtime on modular systems
- Remote monitoring and service support
Single-phase UPS
From 1 to 20 kVA, rack-mount or tower, for offices, tills and small server cabinets.
Three-phase UPS
From 10 to 800 kVA, with parallel operation of several units for N+1 redundancy.
Modular UPS
Hot-swappable power modules, for systems above 1 MW in one frame or in parallel.
Batteries
VRLA or lithium-ion batteries in cabinets, for autonomy from a few minutes to several hours.
External bypass
A manual bypass cabinet for servicing the UPS without disconnecting the load.
| Power | 1 – 20 kVA (1ph), 10 – 800 kVA (3ph) |
|---|---|
| Topology | online double conversion, VFI-SS-111 |
| Efficiency | up to 96 – 97% online, up to 99% in ECO mode |
| Output power factor | up to 1.0 |
| Input current distortion | THDi < 3% |
| Autonomy | typically 5 – 30 min, longer with extra batteries |
| Communication | SNMP, Modbus, volt-free contacts |
The values shown are typical ranges. The exact specification depends on the selected model and is confirmed in the quote.
- Data centers
- Server rooms
- Banks and financial institutions
- Hospitals and clinics
- Medical imaging (MRI, CT, X-ray)
- Telecom operators and base stations
- Industrial automation (PLC, robots)
- TV and radio studios
- Airports and transport infrastructure
- Shopping centers and supermarkets
- Office buildings
- Laboratories and diagnostic centers
Related products
Backup Power Generators
Backup power from 10 to 3000 kVA, with an ATS panel for automatic load transfer.
ViewBatteries
VRLA, OPzV and lithium-ion batteries for UPS, DC systems and generators.
ViewDC Power Systems
Modular rectifier systems for 24, 48, 110 and 220 V DC with battery backup.
ViewStatic Transfer Switches
Transfers the load between two independent sources in less than 5 ms.
ViewBattery Energy Storage System (BESS)
Storage from 50 kWh to several MWh, in a cabinet or container.
View




